<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-06 01-30-27
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 33 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 11 kHz 12337 0,0243
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,99 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:30, 6.04.2024
RT
"Zpravy v pul "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 11 kHz MIN: 9 kHz % above 77 kHz: 0,0243 Acquired: 2024/04/06 1:30:24 Total samples: 12337 Equivalent time: 0:10:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,2 dBr MIN: -1,4 dBr AVE: -0,99 dBr % above 0,2 dBr: 0,0 Last value: -0,2 dBr (2024/04/06 1:30:24) 01:16 01:18 01:20 01:22 01:24 01:26 01:28 01:30 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality